Ball Attach and Recovery System

BA1700R Post Ball Mount Recovery System

  • High Efficiency, can handle most defect types
    (missing, shifted, oversized, undersized, extra, bridging)
  • Capable to handle small ball and narrow pitch
    (Min ball size 60 µm, min ball pitch 100 µm)
  • Capable to handle ball / pillar
  • 25MP camera with unique algorithm to locate and classify defects
  • Special ball container for precise single ball supply
  • Precision flux needle pressure control for secondary dispensing to ensure ball placement accuracy
  • Can be used as integrated or standalone system
Items Specification
Substrate size/pallet size/product thickness
Strip: 180×60~300(L) x 100(W) / Single 10×10~80x80mm (160×310) / Substrate or pallet thickness: 0.1~5mm
Ball diameter and ball pitch
0.06~0.89mm / 0.10~1.5mm
Flux dispensing accuracy
Positioning Accuracy:±10um / Flux dispensing accuracy ±15um
Solder balls supply
Air circular vibration – dispense one ball at a time
Solder ball pick-up mechanism
Ceramic pickup head / automatic optical ball alignment and positioning correction
Solder ball placement accuracy

±15 mm

Image processing system
25MP high speed CCD / Resolution: 6-20 m / Field of view 32×48–100x100mm
Inspection items
Missing ball / Shifted Ball / Extra Ball / Ball Bridging / Oversize or Undersize Ball
Flux dispensing and ball height measurement
Automatic ball height measurement for every ball recovered
Inspection and recovery rate
Inspection time 0.5 sec per FOV / missing ball recovery < 3 sec/ball, remove and replace 5-8sec/ball (depend on defect type)

Recovery Yield

100% based on ball count (based on equipment capability)

Machine dimension

W x D x H 2500mmX1800mmX1650mm / Weight Approx 2,500kg
Machine utility requirements
Power 3 phase 380V ±10% / CDA 5 Kgf/㎠ / Vacuum: 750 mmHg / Power. 5.0KW
Scroll to Top